Tanks, calibration charts, dips & wet-stock variance: how it works
Each tank has a product, capacity, safe fill, reorder level and a calibration chart that turns a dip in millimeters into liters. Daily dips are compared with the book stock; a variance above the tolerance is flagged until a supervisor accepts it.
Lesson 5 of 13 · How it works
How it works
«Tanks & dips» → «Add a tank»: code, grade, capacity, safe fill (often 95 %), the level to order more and the opening stock from today's dip.
Paste the tank's Calibration chart The table that turns a tank's dip in millimeters into liters; between two points the app interpolates. More words in the glossary on the tank page — one «mm volume» pair per line, from the chart the tank supplier or the weights-and-measures office gave you. Between two points the volume is interpolated.
«Record a dip»: the tank, the kind (daily, before / after delivery, spot check), the dip in mm and the water level. The volume, the book stock and the variance are shown at once.
The variance counts the liters sold since the last dip. Above both tolerances in Settings (a % of sales and a number of liters) the dip shows «Above Tolerance The % by which the drawn amount may exceed the LC amount; the latest shipment date and the days after shipment within which documents must reach the bank. More words in the glossary» and is listed under «Variances above tolerance».
A supervisor presses «Accept»: the book stock is set to the dip and the gain or loss is posted to the stock variance account at the average cost. Dips within the tolerance are posted the same way by themselves.
The tank page draws the daily variance of the last 30 dips and lists the dip history; the overview shows the days of stock left.
Where to find it
- Fuel station → Tanks & dips
/admin/fuel/tanks
Settings that change it
- Fuel station → Settings (tolerances, days of stock)
/admin/fuel/settings
Checklist
Before you move on, check that you can:
- Open Fuel station → Tanks & dips
- Tanks & dips → Add a tank: code, grade, capacity, safe fill (often 95 %), the level to order more and the…
- Paste the tank's calibration chart on the tank page — one mm volume pair per line, from the chart the tank…
- Record a dip: the tank, the kind (daily, before / after delivery, spot check), the dip in mm and the water…
- The variance counts the liters sold since the last dip.
Tips and common mistakes
- Dip at the same time every day, before the first sale, so the comparison is fair.
- Volumes are not corrected to 15 °C; note the temperature on deliveries.
- An automatic tank gauge is not read by the app — type its reading as the dip.